Monoclonal antibody against Bovine Herpes Virus type 4 (BHV-4). Read more
Brucella abortus antigen for the Complement Fixation Test Suspension of Brucella abortus biovar 1 Weybridge strain No 99, inactivated by heat and phenol Calibrated to give 50% haemolysis with the second international standard serum (OIESS) diluted 1/200 Read more
The test amplifies: a target sequence an endogenous internal control. Read more
The test amplifies: a target sequence an endogenous internal control, to ascertain presence and correct sample conservation Read more
The test amplifies: a target sequence an endogenous internal control, to ascertain presence and correct conservation of the sample The only commercial BTV PCR which includes a target positive control*: to be extracted along with field samples in order to evaluate extraction efficiency; calibrated at between 10 and 100 times the method detection limit in […] Read more
The test amplifies: a target sequence to detect all Brucella species an endogenous internal control, to ascertain presence and correct conservation of the sample an exogenous internal control to be extracted along with field samples, to evaluate extraction efficiency and confirm the absence of inhibitors in each well. Read more
The test amplifies: a target sequence an endogenous internal control, to ascertain presence and correct conservation of the sample an exogenous internal control to be extracted along with field samples, to evaluate extraction efficiency and confirm the absence of inhibitors in each well The kit includes a calibrated target positive control to validate the entire […] Read more
The test amplifies: a target sequence an endogenous internal control, to ascertain presence and correct conservation of the sample Read more
The test amplifies: a target sequence from member(s) of the MTC (M. tuberculosis, M. bovis, M.africanum, M. microti, M.canetti, M.caprae, and M.pinnipedii) an exogenous internal control to be extracted along with field samples, to evaluate extraction efficiency and confirm the absence of inhibitors in each well Read more
The test amplifies: a target sequence an endogenous internal control, to ascertain presence and correct conservation of the sample Read more
The test amplifies a target sequence in the Map genome and an exogenous mycobacterial control to confirm pathogen lysis and verify the absence of PCR inhibitors.It may be used with the easiest sample preparation protocol on the market, without any weighing step (product code EZPREP, sold separately) Read more
The test amplifies: a target sequence an endogenous internal control, to ascertain presence and correct conservation of the sample Read more
The test amplifies: a target sequence an endogenous internal control, to ascertain presence and correct conservation of the sample an exogenous internal control to be extracted along with field samples, to evaluate extraction efficiency and confirm the absence of inhibitors in each well. Read more
The test amplifies: a target sequence of Coxiella burnetii and Chlamydophila spp. an endogenous internal control, to ascertain presence and correct conservation of the sample Read more
The test amplifies: a target sequence an endogenous internal control, to ascertain presence and correct conservation of the sample It is the only commercial SBV PCR to include a positive target control to be extracted along with field samples in order to evaluate extraction efficiency and confirm the absence of inhibitors in each well. This […] Read more
The test amplifies: a target sequence an endogenous internal control, to ascertain presence and correct conservation of the sample Read more
Each sample is tested in a coated well (even columns) and in an adjacent non-coated well (odd columns). Results are calculated with respect to the corrected sample OD (even well OD – odd well OD). Read more
*Each sample is tested in a coated well (even columns) and in an adjacent non-coated well (odd columns). Results are calculated with respect to the corrected sample OD (even well OD – odd well OD). Read more
The assessment of the diagnostic performance of this ELISA kit on field samples has shown that positive bovine milk samples may be detected in pools of up to 250 samples. * Note: The analysis of milk from small ruminants and the analysis of individual milks are not official EU tests. Read more
*For research use only on human samples Read more
Please contact us for use on other species. Read more
*Note: The ID Screen® product requires 4 control wells per run, and not 6 as with other commercial ELISAs. As a result, the maximum number of field samples which may be tested per plate is 92, and not 90.A protocol including weak positive controls is available upon request. Please contact us for more information. Read more
This test offers a screening and a semi-quantitative/quantitative (titers) protocol, and is suitable for monitoring disease in endemic areas and for post vaccination monitoring. Read more
Note: The ID Screen® product requires 4 control wells per run, and not 8 as with other commercial ELISAs. As a result, the maximum number of field samples which may be tested per plate is 92, and not 88. A protocol including weak positive and blank controls is available upon request. Please contact info@innovative-diagnostics.com for more information. Read more
Detects naturally-infected animals in a vaccinated population provided that animals are vaccinated with BHV-1 gE-deleted vaccines. Read more
Meets FLI (Germany) eradication program specifications for analytical sensitivity. May be used as a screening kit for bulk or pooled milks of up to 50 animals. Read more
The use of a mix of peptide antigens results in superior test performance (sensitivity, specificity, and differentiation between positive and negative results). Read more
Screening and Confirmation formats available. In the confirmation format, each sample is tested in a coated well (even columns) and in an adjacent non-coated well (odd columns). Results are calculated with respect to the corrected sample OD (even well OD – odd well OD). Read more
Please contact IDvet for use on other species.This test does not contain any virus particles Read more
*For research use only on human samples (see References). Contact us. Read more
For research use only on human samples: see References(*). This test does not contain any virus particles. Read more
The detection of anti-IgM antibodies indicates recent infection. This test does not contain any virus particles. Read more
This test may be used with individual samples from minks, ferrets, cats, dogs, cattle, sheep, goats, horses, and any other susceptible species. Read more
Please contact IDvet for use on other species. Read more
Please contact IDvet for use with other species. Read more
Agar gel immunodiffusion (AGID) test for the detection of BLV anti-gP51 antibodies in bovine serum or plasma Bright, distinct precipitation lines facilitate test interpretation Standardised against the European Standard E05 Read more

Hydrosoluble extract, obtained by hot saline treatment of the strain Brucella ovis REO 198 For OCE diagnosis by CFT, as prescribed in the OIE manual. Read more
Rapid slide agglutination antigen for the detection of anti-Brucella abortus, melitensis, or suis antibodies in bovine, ovine, caprine, and porcine species Suspension of Brucella abortus biovar 1 Weybridge strain No 99, inactivated by heat and phenol and coloured with rose bengal stain in an acidified buffer. Calibrated on the OIEISS International Brucella standard serum and the national secondary serum to be positive against a […] Read more