Brucella abortus antigen for the Complement Fixation Test Suspension of Brucella abortus biovar 1 Weybridge strain No 99, inactivated by heat and phenol Calibrated to give 50% haemolysis with the second international standard serum (OIESS) diluted 1/200 Read more
The test amplifies: The only commercial BTV PCR which includes a target positive control*: *The target positive control consists of inactivated BTV, diluted in a virus-negative whole blood matrix, freeze-dried and calibrated at between 10 and 100 times the detection limit of the method (MDL). Read more
The test amplifies: The kit includes a calibrated target positive control to validate the entire PCR process. Read more
The test amplifies a target sequence in the EHDV genome, responsible for the highly infectious epizootic haemorrhagic disease.A qualitative duplex test, it simultaneously amplifies: Read more
Tested pathogens: Anaplasma phagocytophilum, Brucella spp., Campylobacter fetus spp., Chlamydophila spp., Coxiella burnetii, Leptospira spp., Listeria monocytogenes, Neospora caninum, Salmonella spp., Toxoplasma gondii Read more
The test amplifies a target sequence in the genome of the Bluetongue Virus of genotype 3 (BTV-3), responsible of Bluetongue disease.A qualitative Duplex test, it simultaneously amplifies: Read more
The ID Gene™ Bluetongue genotypes 8 and 4 Triplex test simultaneously detects in real time: Read more
The test amplifies: a target sequence to detect all Brucella species an endogenous internal control, to ascertain presence and correct conservation of the sample an exogenous internal control to be extracted along with field samples, to evaluate extraction efficiency and confirm the absence of inhibitors in each well. Read more
This ready-to-use, qualitative Triplex detection kit simultaneously detects in real time: Read more
The test amplifies: a target sequence an endogenous internal control, to ascertain presence and correct conservation of the sample Read more
The ID Gene™ EHDV Advantage Duplex kit is a RT-qPCR kit that amplifies a target sequence in the genome of the EHDV (Epizootic Hemorrhagic Disease Virus), responsible of the Epizootic Hemorrhagic Disease.This kit is a qualitative Duplex test. It simultaneously amplifies target RNA as well as an endogenous non-target positive control. Read more
The test amplifies: a target sequence from member(s) of the MTC (M. tuberculosis, M. bovis, M.africanum, M. microti, M.canetti, M.caprae, and M.pinnipedii) an exogenous internal control to be extracted along with field samples, to evaluate extraction efficiency and confirm the absence of inhibitors in each well Read more
The test amplifies: a target sequence an endogenous internal control, to ascertain presence and correct conservation of the sample Read more
The test amplifies a target sequence in the Map genome and an exogenous mycobacterial control to confirm pathogen lysis and verify the absence of PCR inhibitors.It may be used with the easiest sample preparation protocol on the market, without any weighing step (product code EZPREP, sold separately) Read more
The test amplifies: a target sequence an endogenous internal control, to ascertain presence and correct conservation of the sample Read more
The test amplifies: a target sequence an endogenous internal control, to ascertain presence and correct conservation of the sample an exogenous internal control to be extracted along with field samples, to evaluate extraction efficiency and confirm the absence of inhibitors in each well. Read more
The test amplifies: a target sequence an endogenous internal control, to ascertain presence and correct conservation of the sample It is the only commercial SBV PCR to include a positive target control to be extracted along with field samples in order to evaluate extraction efficiency and confirm the absence of inhibitors in each well. This […] Read more
The test amplifies: a target sequence an endogenous internal control, to ascertain presence and correct conservation of the sample Read more
Technology based upon reagents developed by CIRAD, Montpellier, France. Read more
Each sample is tested in a coated well (even columns) and in an adjacent non-coated well (odd columns). Results are calculated with respect to the corrected sample OD (even well OD – odd well OD). Read more
*Each sample is tested in a coated well (even columns) and in an adjacent non-coated well (odd columns). Results are calculated with respect to the corrected sample OD (even well OD – odd well OD). Read more
The assessment of the diagnostic performance of this ELISA kit on field samples has shown that positive bovine milk samples may be detected in pools of up to 250 samples. * Note: The analysis of milk from small ruminants and the analysis of individual milks are not official EU tests. Read more
Please contact us for use on other species. Read more
*Note: The ID Screen® product requires 4 control wells per run, and not 6 as with other commercial ELISAs. As a result, the maximum number of field samples which may be tested per plate is 92, and not 90.A protocol including weak positive controls is available upon request. Please contact us for more information. Read more
This test offers a screening and a semi-quantitative/quantitative (titers) protocol, and is suitable for monitoring disease in endemic areas and for post vaccination monitoring. Read more
Note: The ID Screen® product requires 4 control wells per run, and not 8 as with other commercial ELISAs. As a result, the maximum number of field samples which may be tested per plate is 92, and not 88. A protocol including weak positive and blank controls is available upon request. Please contact info@innovative-diagnostics.com for more information. Read more
Detects naturally-infected animals in a vaccinated population provided that animals are vaccinated with BHV-1 gE-deleted vaccines. Read more
Meets FLI (Germany) eradication program specifications for analytical sensitivity. May be used as a screening kit for bulk or pooled milks of up to 50 animals. Read more
The use of a mix of peptide antigens results in superior test performance (sensitivity, specificity, and differentiation between positive and negative results). Read more
Screening and Confirmation formats available. In the confirmation format, each sample is tested in a coated well (even columns) and in an adjacent non-coated well (odd columns). Results are calculated with respect to the corrected sample OD (even well OD – odd well OD). Read more
Please contact IDvet for use on other species.This test does not contain any virus particles Read more
*For research use only on human samples (see References). Contact us. Read more
For research use only on human samples: see References(*). This test does not contain any virus particles. Read more
The detection of anti-IgM antibodies indicates recent infection. This test does not contain any virus particles. Read more
This test may be used with individual samples from minks, ferrets, cats, dogs, cattle, sheep, goats, horses, and any other susceptible species. Read more
Please contact IDvet for use on other species. Read more
Please contact IDvet for use with other species. Read more